Hydraulic Component Test Stand
The Starline Model SL1200-15 is a hydraulic component test stand designed to test aircraft components using hydraulic flow and pressure. The system can exercise an actuator in both directions or simply provide pressure and flow through a separate set of hoses. It has the ability to perform high-pressure static testing of components for leaks and operation using a hand pump. The test stand has a polycarbonate panel test chamber for lighting and viewing, and the cabinet is constructed from 304 stainless steel. The system is controlled and safety monitored using a PLC with an HMI panel and a rotating arm for proper positioning.
The following are the technical specifications of the system:
Fluid system:
- Adjustable flow rate: 1 – 15gpm (56.8 lpm)
- Adjustable pump pressure: 400 – 5000psi (344.8 bar)
- Hand pump: up to 10,000psi (689.6 bar)
- Pressure safety relief valve: 5300psi (365.4 bar)
- Filtration (cartridge type replaceable elements): pressure (3-micron), return (10-micron), water removal filter, particle (3-micron), and hand pump (3-micron)
- Supply/return hoses: 3/4 inch diameter (19mm)
- Shut-off valve for supply, return, System A and System B outputs
- System bypass valve PLC controlled
- Directional valve, closed center, System A / System B, PLC control
- Hydraulic oil type: MIL-PRF-83282 or equivalent
Fluid reservoir and controls:
- Capacity: 28 gallons (106 L)
- Fluid level sight glass
- Low level and High level sensors, PLC alarms
- Recirculation pump: 1hp electric motor, independent from main motor operation
- Includes connection ports for mobile hydraulic fluid purifier unit
Fluid heat exchanger and control:
- Heat exchanger motor: 1/2 hp motor
- Independent control to allow cooling without main pump running
- Thermocouple probe
- PLC thermostat control with adjustable on/off settings
Electrical:
- Air-cooled TEFC main motor, 50hp
- Power requirements: 3 phase, 50/60Hz, 380/460VAC
- Main circuit breaker electrical disconnect
- Phase/voltage monitor
- Illuminated E-Stop push button
- Soft starter for main motor
- Overload protection for all motors
- 24VDC power supply with circuit breaker protection
- PLC flow and pressure control, safety monitoring, and control
- Full load amps, voltage, and frequency: Frequency (Hz) Phase Voltage Amps 50 3 380 80A 60 3 460 67A
Mechanical:
- Dimensions:
- Width: 48 in (122 cm)
- Length: 65 in (165 cm)
- Height: 67 in (170 cm)
- Weight:
- Casters: 5 x 2 in (127 x 51mm) polyurethane with swivel and locks
- Cabinet material: 304 stainless steel
- Clear panels: 3/8 in (9.5 mm) clear polycarbonate
The test stand has external controls, including an HMI panel, circuit breaker disconnect with a “lockout” feature, an illuminated mushroom-style E-Stop, a phase/voltage indicator, and an hour meter for testing and maintenance. The fluid level in the reservoir is easily maintained with the use of a sight gauge, and all external fluid connection points include manual shutoff valves. The operator interface uses a programmable logic controller (PLC) and an HMI panel to provide operator control of the hydraulic test stand.